Sensor's Quantum Efficiency / Spectral Response

Sensor's Quantum Efficiency / Spectral Response

It is possible to derive the Quantum Efficiency (QE) from the LIFO data as explained in this page
Here we share some indicative values about results found for each of our sensor's generation.
Official values should be retrieved from the Datasheet but those values give you a first idea on our sprectral response.

Quantum Efficiency for Gen31, Gen40 and Gen41:
LED Wavelength
455nm505nm625nm850nm940nm
Gen31
37%
39%
37%
15%
5%
Gen40
42%
52%
52%
23%
11%
Gen41
60%
78%
69%
28%
13%

Relative Spectral Response for IMX636:
LED Wavelength455nm505nm625nm850nm940nm
IMX63688%100%92%39%18%
Note: this table is relative to the wavelength that has the higher response (505nm)